Hareda
Place: Haryana
Architect: The Elements
BUA: 50,000 Sq. Ft.
Services: Sustainability, PHE, Fire, HVAC & BMS


Green Features
Net Zero Energy Building
Water
- 100% Water Self Sustainable Building
- No water is taken from Municipal Supply completely water self sustainable building with 6 lakh capacity Rainwater harvesting system
Energy
- Stack effect is used to naturally ventilate the building
- Renewable Energy:100% Solar PV usage and its Net Positive. Rated Capacity of Solar PV installed on site is 42kW peak
- East and West windows are oriented south to have easier sun control through shading devices
- The South Façade has Solar Chimneys to aid ventilation for passive zones
- Misting Done in the courtyard to cool the ambient air which is sucked into the building through solar chimneys. The achieved internal RH range from 60 to 75%
- The overall energy performance index of “is 15 Kwh/m2/year compared to conventional design of 75 Kwh/m2/year
GRIHA 5 Star Rated Building with 90 Points
Infosys, Hubballi
Place: Hubballi
Architect: Infosys Limited
BUA: 1.5 Million Sq. Ft.
Services: Sustainability, HVAC, PHE & Fire


Green Features
Green Features
Energy
- HVAC Load is 870 Sq. Ft. /TR
- 38% Savings in overall Energy
- 100% Daylit Building
- Comparison to ASHRAE Base Case & INFOSYS, Hubballi design case - 42% savings on high side part & 23% savings on low side part
Water
- 3 acre of Rainwater Harvesting Pond to meet the freshwater Demand
- 80% saving in freshwater demand using efficient fixtures
- 100% recycle and reuse of treated wastewater for flushing and Landscaping
CO2 Emission
- Operational Co2 Saving: 74 tons/Year
Targeting LEED Platinum Rating
Mindtree Kalinga
Place: Bhubaneswar
Architect: CnT Architects Pvt Ltd
BUA: 1.5 Million Sq. Ft.
Services: Sustainability, HVAC, PHE & Fire


Green Features
Water
- 100% Water Self Sustainable campus for Phase 1 Occupancy of 1000 people
- Pond was constructed before construction of building to divert the site water and use for construction activities
- 3 acre of Pond to retain the storm water and make the development self sustainable by using the harvested rainwater
Energy
- Passive Cooling system was designed to deal with hot and humid climate
- Stack effect system is designed for hostel block passive cooling. Cold and de-humidified air is pushed through the stack from roof into roof, further the air gets exhausted into living room and than into atrium. At the top of atrium we have an exhaust chimney, which get heated with sunlight and pulls the relatively cold air
- 45% Savings in Energy
- EPI of 91 kWh/m2/Year has been achieved using energy efficient design
LEED PLATINUM RATED BUILDING
Infosys, Bhubaneswar
Place: Bhubaneswar
Architect: Infosys Limited
BUA: 4.5 Lakh Sq. Ft.
Services: Sustainability, HVAC


Green Features
Water
- Horizontal & Vertical Shading devices have been designed for the project ,which completely shades the building and reduces the solar heat gain
- Envelope Load of 0.79 w/Sq. Ft. has been achieved
- 80% Areas are completely Daylit
- Air-condition load is 675 Sq. Ft. /TR compared to conventional building of 300 Sq. Ft. / TR
- EPI is 74 kWh/m2/y compared to 200 kWh/m2/yr
IGBC Platinum Rated Building
Umiya Velociti
Place: Bangalore
Architect: Umiya Developers
BUA: 0.75 Million Sq. Ft.
Services: Sustainability, PHE, Fire, HVAC & BMS


Green Features
- Optimized Façade Design
- 20% savings in operational cost
- 45% Saving in Water Consumption
- 5% Reduction in Capital Cost Compared to Conventional Design
Bharatiya City SEZ
Place: Bangalore
Architect: Milestones
BUA: 1.5 Million Sq. Ft.
Services: Sustainability, PHE, Fire, HVAC & BMS


Green Features
Following are the key parameters has been adopted during the building design,
- Efficient HVAC ,PHE and Electrical System Design
- Cost-Effectiveness
- Comfort
- Environmental Sustainability
- Optimize Operational and Maintenance Practices
- Smart Functionality